| Lugar de origen: | NINGBO, CHINA |
| Nombre de la marca: | BRANDO |
| Certificación: | None |
| Número de modelo: | BB13541204-L |
| Cantidad de orden mínima: | 200 |
|---|---|
| Precio: | Negociable |
| Detalles de empaquetado: | Cajas interiores, cajas de cartón, palés |
| Tiempo de entrega: | Negociación |
| Condiciones de pago: | T/T, Paypal, Unión Occidental |
| Capacidad de la fuente: | 100000 unidades por mes |
| Tamaño del agujero: | 13.5 mm | Altura: | 41.2m m |
|---|---|---|---|
| Ancho: | 36.0 mm | Voltaje: | 220 V CA, 24 V CC |
| Fuerza: | 25VA, 20W | Tipo de conexión: | DIN43650A |
| Clase de protección: | ip65 | Clase de aislamiento: | F, H |
| Material esmaltado del alambre: | cobre | Aplicación: | Válvula de pulso SBFEC antigua serie DMF |
| Resaltar: | BFEC Pulse Valve Solenoid Coil,BFEC Pulse Valve Coil,SBFEC Pulse Jet Valve Coil |
||
24VDC DMF Series Old Version Pulse Valve Solenoid Coil 24V DC24V
This Coil can be used in all series Old Version SBFEC type pulse valve, like DMF-Z series right angle threaded diaphragm valve, DMF-Y series Embedded diaphragm valve, DMF-ZM series right angle diaphragm valve with dresser nut and DMF-T series Straight diaphragm valve. The movable iron core in the solenoid valve coil attracts the movement of the coil when the valve is energized, driving the valve core to move, thereby changing the conduction state of the valve. The input changes with the position of the iron core. When the inductance is small, the current flowing through the coil will increase.
Hole Size:13.5mm
Height:41.2mm
Width:36.0mm
Voltages:AC220V, DC24V
Power:25VA, 20W
Connection Type:DIN43650A
Protection Grade:IP65
Insulation Class:F, H
Enameled wire material:Copper
Application:BFEC Old DMF Series Pulse Valve
Dimension of BFEC Type Solenoid Pulse Valve Coil:
![]()
Specification of DMF Series Solenoid Coil Repair Kits:
Application Example:
![]()
Common problems of electromagnetic pulse valve coil
The coil of the electromagnetic pulse valve is burnt out. The wiring of the electromagnetic pulse valve can be removed and measured with a multimeter. If it is open, the coil of the electromagnetic pulse valve is burnt out. However, it is burnt, so it is necessary to prevent rainwater from entering the solenoid valve. In the end, the spring is too stiff, the reaction force is too large, the coil turns are too few, and the suction force is not enough, and the coil can be burned.
When the coil of the solenoid valve is in working state (energized), the iron core is attracted to form a closed magnetic circuit. That is, when the inductance is at the maximum state. The heating is normal, but the iron core cannot be pulled in smoothly when energized, the coil inductance is reduced, the impedance is reduced, and the current is increased accordingly. This causes the coil current to be too large and the lifespan is affected. It can't even be fully attracted normally, so that the coil is often in a state of less impedance than normal when it is energized, which may be the factor of the coil.
Product Characteristic:
1. Using high quality wire which has UL approved;
2. Using high quality permeablity magnetic material which contain low carbon;
3. Using high quality housing material like PA66, PBT, PPS, BMC and so on;
4. Insulation class can be B, F, H, N, C;
5. Protection class can be IP65, IP67 & IP69K;
6. We also offer special coils like ex-proof coils, water proof coils and so on;
7. If you have special requirement, pls feel free to contact us.
Focus on your demands, Offer you best solution:
√ Contact us if some points you have doubt
√ Contact us if somewhere need to change
√ Contact us if not the one you are looking for
√ Contact us if you are doing designing
Welcome to your any question and inquiry!
Persona de Contacto: Mr. Brandon Bao
Teléfono: 86-13454729544
Fax: 86-574-83879820
3" filtro de Jet Solenoid Valve For Bag del pulso del diafragma de DMF-Z-76S BFEC
Tipo colector de CA25DD Goyen de Jet Diaphragm Valve For Dust del pulso de la serie de la DD
1" tipo pulso Jet Valve For Dust Removal de SCG353A044 ASCO del diafragma
EVR 3 NC 032F8107 1/4" tipo válvula electromagnética 220VAC de Danfoss de la refrigeración
1028/3 Castel Type 3/8" válvula electromagnética HM2 220VAC 230VAC de la refrigeración
Tipo válvula electromagnética 042H1128 042H1132 de EVRA 40 EN-JS1025 Danfoss del amoníaco
Diafragma de C113443 C113444 para la válvula SCG353A043 SCG353A044 del pulso de ASCO
Diafragma para la válvula 1,5" del pulso de BFEC DMF-Z-40S DMF-ZM-40S DMF-Y-40S
Válvula CA76T CA76MM de Kit For Goyen Pulse Solenoid del diafragma de K7600 K7601